建筑施工鋼筋網(wǎng)片一般有三種類型:疊塔法,屈曲法和扁平法。重疊法和屈曲法的優(yōu)點(diǎn)是鋼筋數(shù)量少,安裝方便,但接頭處的鋼筋數(shù)量多,影響了鋼筋網(wǎng)的應(yīng)力。平面重疊法重疊點(diǎn)處的水平鋼筋和垂直鋼筋在同一平面上,應(yīng)力較好,但重疊長度大于前者。以下是安裝建筑網(wǎng)片的操作規(guī)范。希望我們在施工過程中嚴(yán)格按照操作規(guī)范進(jìn)行安裝。以確保我們的人身。
There are generally three types of steel mesh in Construction: Tower stacking method, buckling method and flat method. The advantages of overlapping method and buckling method are that the number of steel bars is small and the installation is convenient, but the number of steel bars at the joint is large, which affects the stress of the steel mesh. The horizontal reinforcement and the vertical reinforcement at the overlapping point of plane overlapping method are in the same plane, the stress is better, but the overlapping length is greater than the former. The following is the operation specification for installation of building mesh. We hope that we will install in strict accordance with the operation specifications in the construction process. To ensure our personal safety.
如何安裝和使用建筑鋼筋網(wǎng)
How to install and use building steel fabric
有兩種類型的建筑網(wǎng)片搭接:受力搭接和非受力搭接。根據(jù)規(guī)格要求,搭接長度和錨定長度指定如下:
There are two types of building mesh lap: stressed lap and unstressed lap. According to the specifications, the lap length and anchor length are specified as follows:
1.當(dāng)承重鋼筋采用搭接法或屈曲法時,每個建筑網(wǎng)在搭接范圍內(nèi)應(yīng)少有一個橫向鋼筋,且兩個建筑網(wǎng)中靠外面的一個之間的距離不應(yīng)小于小于50mm,且兩塊建筑網(wǎng)的搭接長度應(yīng)不小于d(混凝土強(qiáng)度等于C35)且不小于200mm;當(dāng)鋼筋采用扁平鋼筋法時,兩塊鋼筋網(wǎng)的搭接長度應(yīng)不小于37d(混凝土強(qiáng)度等于C35),且不小于300mm。
1. When the load-bearing reinforcement adopts the lapping method or the buckling method, there shall be at least one transverse reinforcement in the lapping range of each building network, and the distance between one of the two building networks close to the outside shall not be less than 50 mm, and the lapping length of the two building networks shall not be less than D (concrete strength is equal to C35) and not less than 200 mm; when the reinforcement adopts the flat reinforcement method, the lapping of the two building networks The joint length shall not be less than 37d (concrete strength equal to C35) and not less than 300mm.
如何安裝和使用建筑鋼筋網(wǎng)
How to install and use building steel fabric
2,無應(yīng)力鋼筋采用搭接或屈曲方式時,每個鋼筋網(wǎng)在搭接范圍內(nèi)少有一根主鋼筋,搭接長度應(yīng)不小于20d且不小于150mm;采用平面重疊法時,重疊長度應(yīng)不小于20d且不小于200mm。
2. When the unstressed reinforcement is overlapped or buckled, there shall be at least one main reinforcement within the overlapping range of each reinforcement mesh, and the overlapping length shall be no less than 20d and no less than 150 mm; when the plane overlapping method is adopted, the overlapping length shall be no less than 20d and no less than 200 mm.
3.冷軋帶肋鋼絲網(wǎng)的錨固長度應(yīng)不小于28d(錨固長度上有橫向鋼筋且混凝土強(qiáng)度等于C35時)且不小于200mm。
3. The anchoring length of cold-rolled ribbed steel wire mesh shall not be less than 28d (when there is transverse reinforcement on the anchoring length and the concrete strength is equal to C35) and not less than 200mm.
The above is about the use of building mesh, which is provided by Jinan Steel wholesale. If you want to know more, please consult us